This article covers Part 1 of our three-part series on forensic CE data analysis.
Capillary Electrophoresis (CE) is currently the standard method forensic labs use to analyze STRs from crime scene samples. However, setting up a lab's SOPs for CE analysis of STRs is typically performed by a validation team, which means casework analysts might not be familiar with everything that goes into getting a CE workflow put in place.
Capillary Electrophoresis (CE) is a crucial tool in forensic DNA analysis, providing accurate methods for DNA profiling from crime scene samples. By separating DNA fragments based on size and charge, CE enables forensic scientists to analyze Short Tandem Repeats (STRs)—highly variable regions in human DNA that are essential for identification and matching biological evidence.
During the forensic CE process, DNA fragments are separated in a capillary tube filled with a buffer solution. An electric field is applied, causing DNA fragments to migrate at different rates depending on their size. The resulting electropherogram is then analyzed to assign STR alleles and construct a DNA profile.
Proper analytical thresholds are vital for accurate forensic capillary electrophoresis interpretation. The analytical threshold (AT) in forensic DNA represents the minimum peak height at which a signal can be distinguished from background noise with statistical confidence. Setting appropriate ATs is crucial as they directly impact whether true allelic peaks are detected or missed during analysis.
There are numerous validated methodologies for establishing analytical thresholds:
*21st International Symposium on Human Identification Mixture Interpretation Workshop: Principles, Protocols, and Practice, October 11, 2010 – San Antonio, TX
It's worth noting that older methods based on extreme value calculations (e.g., 2X peak-to-trough difference) are no longer recommended by OSAC as they "do not address the statistical confidence of a given analytical threshold" and "can be easily skewed by outlier data."
A common recommended method follows these steps:
When implementing analytical thresholds:
GeneMarkerHID software provides a validation assistance tool specifically for determining analytical thresholds. This automated tool can significantly reduce the time-consuming process of manually removing artifact peaks, ensuring consistent application of rules, and eliminating the potential for missing peaks during the manual deletion process.
Stutter artifacts—smaller peaks that appear adjacent to true alleles—are common in CE analysis and must be properly identified. Traditional approaches use marker-specific stutter filters in forensic genetics (typically average + 3 standard deviations), but these fail to account for variations within markers.
Stutter patterns vary significantly based on:
When stutter filters are set too high, minor contributor peaks may be missed. When set too low, the number of required analyst interventions increases, as does the potential for mistakenly including artifact peaks in DNA mixture interpretation.
The impact of stutter varies dramatically between different repeat types:
For complex markers, stutter patterns may follow a bimodal distribution based on the longest uninterrupted stretch (LUS) of repeats. Different alleles within the same marker can have significantly different stutter percentages, ranging from as low as 5% to nearly 18% in some cases.
Advantages
Allele-specific stutter filters offer significant advantages over traditional marker-wide filters:
Research by Dr. John Shiman and colleagues at the Connecticut State Lab demonstrated these advantages through validation studies:
To implement allele-specific stutter filters:
Software like GeneMarkerHID allows you to set specific stutter percentages for each position type (minus, plus) for each allele, ensuring accurate filtering even in complex mixture situations.
Even with stringent protocols, contamination remains a persistent concern in forensic laboratories. A comprehensive DNA contamination database helps identify potential sources of contamination quickly and efficiently.
A contamination database should include DNA profiles from:
To establish an effective contamination database:
GeneMarker HID software enables contamination checks against your elimination database with just a few clicks. The software can automatically flag matches between casework samples and profiles in your contamination database, with adjustable settings to account for the complexity of mixture samples.
Positive and negative controls are vital for ensuring the reliability of the analysis:
Forensic internal control probes are essential to verify the validity of CE results:
GeneMarker HID software automatically evaluates these patterns and flags potential issues, helping analysts quickly identify the root cause of problems and determine appropriate next steps. This automation enhances efficiency and consistency in the interpretation of control results.
Forensic labs must use standardized analysis templates to define important parameters for each sample. Templates ensure consistency, reduce user variability, and simplify the analysis process.
Key template parameters include:
Templates should also:
To prevent accidental modifications to validated templates, software should implement user access rights where administrators establish and modify settings, while routine analysts can only apply—but not modify—validated templates. GeneMarkerHID implements this through user management controls that restrict access to template modification based on user roles.
A Laboratory Information Management System (LIMS) plays a critical role in managing forensic data and streamlining workflows. By integrating with CE instruments, LIMS helps track samples, store results, and generate reports efficiently.
Key LIMS features include:
For efficient workflow integration:
This integration reduces administrative workload and enhances the overall efficiency of forensic data management.
GeneMarkerHID's CODIS-compatible reporting automatically excludes samples with quality flags, ensuring only high-quality data is exported. The software allows administrators to establish LIMS report settings, with locked configurations that prevent analysts from accidentally changing report formats and creating compatibility issues with the laboratory's LIMS system.
Implementing tiered user access ensures validated SOPs are followed:
An audit trail records all actions taken during the analysis, ensuring full traceability of edits and changes. This is crucial for maintaining evidence integrity and accountability, especially when the data is used in legal proceedings.
Each sample should have its own audit trail that documents:
This level of documentation ensures that the analysis of each sample can be reconstructed if necessary. When an analyst makes edits to genotyping data, such as deleting a peak, GeneMarkerHID prompts them to add comments explaining the rationale. These comments are stored with the project and can be referenced later to justify decisions. The software provides customizable comment templates for commonly used explanations, streamlining the documentation process while ensuring thoroughness.
Project-level audit trails capture broader actions:
Implementing robust Quality Assurance (QA) and Quality Control (QC) procedures in forensic labs is vital to ensure accurate and reproducible results. Modern forensic DNA software includes automated quality flags that provide analysts with real-time alerts:
GeneMarkerHID generates comprehensive audit trails for reporting for entire projects, capturing analyst IDs, software versions, institution names, and all edits made throughout the analysis process. These audit trails can span dozens of pages for complex projects and can be saved as PDFs or reviewed within the software. This comprehensive documentation is essential for courtroom testimony and for meeting accreditation requirements such as ISO 17025.
Establishing clear workflows and standardized analysis parameters is essential for the success of forensic capillary electrophoresis (CE) data analysis.
By implementing effective SOPs, using internal controls, automating quality checks, and integrating LIMS systems, forensic labs can ensure accurate, reproducible, and legally sound results.
These practices ultimately support justice by delivering reliable forensic evidence that stands up to scrutiny in court. The field of forensic DNA analysis continues to evolve, but these fundamental principles provide a solid foundation for generating accurate, reproducible, and legally sound results that serve the justice system effectively.
By standardizing the entire process from sample collection to final report generation, forensic labs maintain high standards and ensure results that are both reliable and defensible in a court of law.